<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-07 17-07-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 61 dBuV SANDELS
Pilot RDS Phase Difference
4.7 kHz 5.8 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
8 kHz 67 kHz 16374 7,8600
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,3 dBr 4,49 dBr 5,4 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 67 kHz MIN: 8 kHz % above 76 kHz: 7,8600 Acquired: 2025/04/07 17.06.17 Total samples: 16374 Equivalent time: 0:13:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,4 dBr MIN: 3,3 dBr AVE: 4,49 dBr % above 12,2 dBr: 0,0 Last value: 4,6 dBr (2025/04/07 17.06.17) 16.52 16.54 16.56 16.58 17.00 17.02 17.04 17.06 0 2 4 6 Pm [dBr]